- F
- L
- E
- X
Proline Prosonic Flow G 300 for natural and process gas measurement in the chemical and in the oil and gas industries.
- F
- L
- E
- X
3D QR code for Prosonic Flow G
Proline Prosonic Flow G 300 for natural and process gas measurement in the chemical and in the oil and gas industries.
Specs at a glance
-
Max. measurement error
Volume flow (standard):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Volume flow (optional calibration):
‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (standard):
‐ ±1.2 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2.1 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (optional calibration):
‐ ±0.8 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Sound Velocity: ±0.2 % o.r. -
Measuring range
Gas: 0.3 m/s to 40 m/s
-
Medium temperature range
-50 to 150 °C (-58 to +302°F)
-50 to 100 °C (-58 to +212°F) with integrated pressure cell -
Max. process pressure
0.7 to 101 bar a (10.15 to 1464.88 psi a)
-
Wetted materials
Measuring tube: 1.4408/1.4409 (CF3M)
Transducer: 1.4404 (316, 316L), Titan Grade 2
Field of application
For a wide range of gas applications Prosonic Flow G provides reliable flow measurement, even with wet gas and changing gas properties and compositions. A pressure-rated sensor housing with rupture disc limits safety risks. The compact transmitter offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables compliance and process safety at all times.
The measuring principle is unaffected by gas composition
Accurate measurement of natural and process gas in the chemical as well as oil and gas industries.
Device properties:
Direct measurement: flow, pressure & temperature
Wetted parts: titanium / 316L
Maximum measuring accuracy: 0.5 %
Compact dual-compartment housing with up to 3 I/Os
Backlit display with touch control and WLAN access
Remote display available
Benefits
Flexible device with user-definable gas mixtures for demanding measuring tasks
Maximum reliability even with humid or wet gas – sensor design insensitive to condensate
High-performance process control – real-time pressure- and temperature-compensated values
Efficient solution – multivariable, no pressure loss
Full access to process and diagnostic information – numerous, freely combinable I/Os
Reduced complexity and variety – freely configurable I/O functionality
Integrated verification – Heartbeat Technology
Videos
-
Check it out! Scan the code, download the 3D QR app and explore Prosonic Flow G on your own.
-
The Ultrasonic Flow Measuring Principle
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Measuring principle
Ultrasonic flow
-
Product headline
Highly robust gas specialist for fluctuating process conditions with compact, easily accessible transmitter.
Flexible device with user-definable gas mixtures for demanding measuring tasks.
Accurate measurement of natural and process gas in the chemical as well as oil and gas industries. -
Sensor features
Maximum reliability even with humid or wet gas – sensor design insensitive to condensate. High-performance process control – real-time pressure- and temperature-compensated values. Efficient solution – multivariable, no pressure loss.
Direct measurement: flow, pressure & temperature. Wetted parts: titanium / 316L. Maximum measuring accuracy: 0.5 %. -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. -
Nominal diameter range
DN 25 to 300 (1 to 12")
-
Wetted materials
Measuring tube: 1.4408/1.4409 (CF3M)
Transducer: 1.4404 (316, 316L), Titan Grade 2 -
Measured variables
Volume flow, corrected volume flow, mass flow, flow velocity, speed of sound, pressure, temperature, density, dynamic viscosity, energy flow, Wobbe index, methane fraction, calorific value, molar mass
-
Max. measurement error
Volume flow (standard):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Volume flow (optional calibration):
‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (standard):
‐ ±1.2 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2.1 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (optional calibration):
‐ ±0.8 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Sound Velocity: ±0.2 % o.r. -
Measuring range
Gas: 0.3 m/s to 40 m/s
-
Max. process pressure
0.7 to 101 bar a (10.15 to 1464.88 psi a)
-
Medium temperature range
-50 to 150 °C (-58 to +302°F)
-50 to 100 °C (-58 to +212°F) with integrated pressure cell -
Ambient temperature range
-40 to 60 °C(-40 to +140 °F)
Optional: -50 to 60 °C(-58 to +140 °F) -
Sensor housing material
Stainless Steel, 1.4404(316/316L), 1.4408/1.4409 (CF3M)
-
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
Polycarbonate -
Degree of protection
Compact version: IP66/67, type 4X enclosure.
Optional: External WLAN antenna: IP67 -
Display/Operation
4-line backlit display with Touch Control (operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
3 outputs:
4-20 mA HART (active/passive)
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, Modbus RS485
-
Power supply
24V DC
100 to 230 V AC
AC 100 to 230 V / DC 24 V (non harzardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, JPN, EAC, UK Ex, KC
-
Product safety
CE, C-tick
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
NACE MR0175/MR0103
-
-
Technical Information (TI)
TI Proline Prosonic Flow G 300
-
Technical Information (TI)
English version - 01/2024New version available in EnglishUltrasonic time-of-flight flowmeter
EN 31/01/202416/09/201905/08/2019Language:
English
Version:
31/01/2024
File size:
6 MB
File name:
TI01385DEN_0324-00.pdf
-
-
-
Operating Instruction (BA)
BA Proline Prosonic Flow G 300
-
Operating Instruction (BA)
English version - 01/2024New version available in EnglishUltrasonic time-of-flight flowmeter
HARTEN 31/01/202416/09/201905/08/2019Language:
English
Version:
31/01/2024
File size:
8.3 MB
File name:
BA01834DEN_0324-00.pdf
-
-
-
Operating Instruction (BA)
BA Proline Prosonic Flow G 300
-
Operating Instruction (BA)
English version - 01/2024New version available in EnglishUltrasonic time-of-flight flowmeter
Modbus RS485EN 31/01/202416/09/201905/08/2019Language:
English
Version:
31/01/2024
File size:
7.3 MB
File name:
BA01835DEN_0324-00.pdf
-
-
-
Device Parameter (GP)
GP Proline Prosonic Flow G 300
-
Device Parameter (GP)
English version - 01/2024New version available in EnglishUltrasonic time-of-flight flowmeter
Modbus RS485EN 31/01/202405/08/2019Language:
English
Version:
31/01/2024
File size:
2.8 MB
File name:
GP01131DEN_0224-00.pdf
-
-
-
Device Parameter (GP)
GP Proline Prosonic Flow G 300
-
Device Parameter (GP)
English version - 01/2024New version available in EnglishUltrasonic time-of-flight flowmeter
HARTEN 31/01/202405/08/2019Language:
English
Version:
31/01/2024
File size:
2.4 MB
File name:
GP01130DEN_0224-00.pdf
-
-
-
Short Instruction (KA)
KA Flowmeter Proline Prosonic Flow G
-
Short Instruction (KA)
English version - 01/2024New version available in EnglishUltrasonic time-of-flight sensor
EN 31/01/202405/08/2019Language:
English
Version:
31/01/2024
File size:
949.1 KB
File name:
KA01374DEN_0224-00.pdf
-
-
-
Short Instruction (KA)
KA Proline 300
-
Short Instruction (KA)
English version - 01/2024New version available in EnglishHART transmitter
with ultrasonic time-of-flight sensorEN 31/01/202405/08/2019Language:
English
Version:
31/01/2024
File size:
2 MB
File name:
KA01375DEN_0224-00.pdf
-
-
-
Short Instruction (KA)
KA Proline 300
-
Short Instruction (KA)
English version - 01/2024New version available in EnglishModbus RS485 transmitter
with ultrasonic time-of-flight sensorEN 31/01/202405/08/2019Language:
English
Version:
31/01/2024
File size:
2.1 MB
File name:
KA01376DEN_0224-00.pdf
-
-
-
Installation Instructions (EA)
EA Replacing the sensor, gasket for sensor and the pressure cell
-
Installation Instructions (EA)
English version - 03/2024New version available in EnglishProsonic Flow G 300, 500-digital
EN 15/03/202402/08/202215/02/202101/04/202030/09/2019Language:
English
Version:
15/03/2024
File size:
767.1 KB
File name:
EA01254DA2_0624-00.pdf
-
-
-
Installation Instructions (EA)
EA Replacing the electronics
-
Installation Instructions (EA)
English version - 09/2025New version available in EnglishProline 300, 500, 500-digital
EN 30/09/202501/01/202401/07/202301/06/202131/07/2020Language:
English
Version:
30/09/2025
File size:
1.6 MB
File name:
EA01145DA2_0925-00.pdf
-
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
Related products