This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
Measuring principle
Coriolis
-
Product headline
The chemically resistant single‐tube flowmeter with a compact or remote transmitter. Highly accurate measurement of liquids and gases in applications requiring highest corrosion resistance.
-
Sensor features
Maximum safety for chemically aggressive fluids – corrosionresistant wetted parts. Fewer process measuring points – multivariable measurement (flow, density, temperature). Spacesaving installation – no in/outlet run needs. Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2").
-
Transmitter features
Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 50 (³⁄₈ to 2")
-
Wetted materials
Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.15 %
Volume flow (liquid): ±0.15 %
Mass flow (gas, Tantalum only): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Tantalum: –50 to +150 °C (–58 to +302 °F)
Ziconium: –50 to +200 °C (–58 to +392 °F) -
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
2‐line backlit display with push buttons
Configuration via local display and operating tools possible -
Outputs
3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive) -
Inputs
Status input
-
Digital communication
HART
PROFIBUS PA -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
PED, CRN -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Measuring principle
Coriolis
-
Product headline
The chemically resistant single‐tube flowmeter with a compact or remote transmitter. Highly accurate measurement of liquids and gases in applications requiring highest corrosion resistance.
-
Sensor features
Maximum safety for chemically aggressive fluids – corrosionresistant wetted parts. Fewer process measuring points – multivariable measurement (flow, density, temperature). Spacesaving installation – no in/outlet run needs. Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2").
-
Transmitter features
Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 50 (³⁄₈ to 2")
-
Wetted materials
Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.15 %
Volume flow (liquid): ±0.15 %
Mass flow (gas, Tantalum only): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Tantalum: –50 to +150 °C (–58 to +302 °F)
Ziconium: –50 to +200 °C (–58 to +392 °F) -
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
2‐line backlit display with push buttons
Configuration via local display and operating tools possible -
Outputs
3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive) -
Inputs
Status input
-
Digital communication
HART
PROFIBUS PA -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
PED, CRN -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Measuring principle
Coriolis
-
Characteristic / Application
Balanced single-tube system, "Fit-and-Forget" installation
Design:
Easy to clean, hygienic, careful handling of the medium
- chemically resistant material -
Ambient temperature
-20...+65°C
(-4...+140°F) -
Process temperature
-50...+200°C
(-58...+392°F) -
Process pressure
PN 40
Cl 150...300
JIS 10...20K -
Wetted parts
Zirconium 702/R60702
-
Output
4...20 mA
Pulse/Frequency
Status -
Certificates / Approvals
ATEX
FM
CSA
-
Measuring principle
Coriolis
-
Product headline
The chemically resistant single‐tube flowmeter with a compact or remote transmitter. Highly accurate measurement of liquids and gases in applications requiring highest corrosion resistance.
-
Sensor features
Maximum safety for chemically aggressive fluids – corrosionresistant wetted parts. Fewer process measuring points – multivariable measurement (flow, density, temperature). Spacesaving installation – no in/outlet run needs. Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2").
-
Transmitter features
Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 50 (³⁄₈ to 2")
-
Wetted materials
Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.15 %
Volume flow (liquid): ±0.15 %
Mass flow (gas, Tantalum only): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Tantalum: –50 to +150 °C (–58 to +302 °F)
Ziconium: –50 to +200 °C (–58 to +392 °F) -
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
2‐line backlit display with push buttons
Configuration via local display and operating tools possible -
Outputs
3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive) -
Inputs
Status input
-
Digital communication
HART
PROFIBUS PA -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
-
Technical Information (TI)
PROMASS 80/83 I/H Technical
-
Technical Information (TI)
English version - 12/2005New version available in EnglishCoriolis Mass Flow Measuring System , the single-tube system with
fit-and-forget design: easy to clean hygienic minimal shear stress
on fluids.EN 01/12/200515/10/2003Language:
English
Version:
01/12/2005
File size:
878.5 KB
File name:
TI052DEN.pdf
-
-
-
Technical Information (TI)
Proline Promass 80H, 83H Technical Information
-
Technical Information (TI)
English version - 03/2014New version available in EnglishCoriolis flowmeter
The chemically resistant single-tube with a compact or remote
transmitterEN 04/03/201416/03/201101/06/201025/01/201001/09/2008Language:
English
Version:
04/03/2014
File size:
711.9 KB
File name:
TI00074DEN_1414.pdf
-
-
-
Operating Instruction (BA)
Proline Promass 80 PROFIBUS PA Operating Instructions
-
Operating Instruction (BA)
English version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System (withPROFIBUS PA interface) for
measuring the mass flow rate, density and temperature of fluids and
gases.The description of the device functions are in a separate
documentation.EN 15/10/201208/06/201001/11/200801/12/200701/12/2006Language:
English
Version:
15/10/2012
File size:
2.1 MB
File name:
BA00072DEN_1312.pdf
-
-
-
Operating Instruction (BA)
Proline Promass 80 PROFIBUS PA Description of Device Functions
-
Operating Instruction (BA)
English version - 06/2010New version available in EnglishDescription of the device functions (0ptions and inputs). Additional
documentation for Operating Instructions PROline Promass 80 PROFIBUS PA.EN 08/06/201001/11/200801/12/200701/12/200501/06/2001Language:
English
Version:
08/06/2010
File size:
743 KB
File name:
BA073DEN_0610.pdf
-
-
-
Operating Instruction (BA)
Proline Promass 80 HART Operating Instructions
-
Operating Instruction (BA)
English version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System for measuring the mass flow rate,
density and temperature of fluids and gases. The descriptionof the
device functions are in a separate documentation.EN 15/10/201201/03/201001/09/200801/12/200601/12/2005Language:
English
Version:
15/10/2012
File size:
1.8 MB
File name:
BA00057DEN_1312.pdf
-
-
-
Operating Instruction (BA)
Proline Promass 80
-
Operating Instruction (BA)
English version - 09/2008New version available in EnglishDescription of the device functions (0ptions and inputs). Additional
documentation for Operating Instructions PROline Promass 80.EN 01/09/200801/12/200501/11/200415/10/200301/11/2001Language:
English
Version:
01/09/2008
File size:
1.2 MB
File name:
BA058DEN_0908.pdf
-
-
-
Short Instruction (KA)
Proline Promass 80 Brief Operating Instructions
-
Short Instruction (KA)
English version - 08/2015New version available in EnglishCoriolis Mass Flow Measuring System
EN 06/08/201515/10/201201/07/2007Language:
English
Version:
06/08/2015
File size:
1.3 MB
File name:
KA00023DEN_1415.pdf
-
-
-
Installation Instructions (EA)
Replacing Power supply and display Installation Instructions
-
Installation Instructions (EA)
English version - 11/2018New version available in EnglishPromag 50, 51, 53, 55, Promass 40, 80, 83, 84, 8ME, Cubemass DCI 8CN,
CNGmass DCI 8DF, Prosonic Flow 90, 93, t-mass 65EN 15/11/201818/11/2011Language:
English
Version:
15/11/2018
File size:
455.1 KB
File name:
EA00063DA2_1518.pdf
-
-
-
Installation Instructions (EA)
Replacing interface parts Installation Instructions
-
Installation Instructions (EA)
English version - 04/2019New version available in EnglishPromass 40, 80, 83, 84, Cubemass 8CN, CNGmass 8DF
EN 01/04/201917/11/2011Language:
English
Version:
01/04/2019
File size:
787.5 KB
File name:
EA00036DA2_1519.pdf
-
-
-
Installation Instructions (EA)
Replacing connecting cable Installation Instructions
-
Installation Instructions (EA)
English version - 10/2018New version available in EnglishPromass 60, 63, 64, 80, 83, 84
EN 01/10/201801/12/2009Language:
English
Version:
01/10/2018
File size:
293.1 KB
File name:
EA00081DA2_1218.pdf
-